200 W cooling class
The current research baseline targets 200 W cooling for a 150 L cold box, with a modeled COP of 0.424.
Model → validate → gate
The project combines Ziegler–Trepp thermodynamic implementation, CoolProp comparisons, CFD, CAD and a documented open-gap/decision register.
What has been established
Pure-fluid comparisons against CoolProp cover 12 states with a maximum absolute temperature difference of 0.63 °C and a mean of 0.32 °C. This is not mixture VLE validation; NH₃–H₂O mixture-data validation remains an open research item.
Evidence layer
The repository includes thermodynamic modeling, a 1.59 m² CPC collector basis, OpenFOAM heat-transfer work, FreeCAD/CadQuery/Build123D paths, component sizing and a 35-item quantity-only BOM.